|  | 
| |   기술자료 |  | | Industries Syringe                                                         Pump & Micro Piston                                                         Pump in Spectrometers                                                          (Release Time:2015-10-08)     |  | Application Introduction:                                                           Identifying the substance                                                         and confirming its chemical                                                         composition and relative                                                         content based on its                                                         spectrum is called spectrum                                                         analysis. Spectrum analysis                                                         has many advantages                                                         when compared with other                                                         analysis methods: such                                                         as its high sensitivity,                                                         better selectivity,                                                         fast and easy operation,                                                         strong anti-interference                                                         performance, high accuracy,                                                         which has been developed                                                         rapidly. The spectrometer,                                                         used for spectrum analysis,                                                         has become an important                                                         piece of equipment in                                                         laboratory analysis,                                                         it is widely used in                                                         air pollution, water                                                         pollution, food hygiene,                                                         metal industry, etc.                                                         Typically, a spectrometer                                                         consists of 5 components:                                                         a light source, a sample                                                         processing system, a                                                         wavelength selector,                                                         detector and a signal                                                         processing system. The                                                         sample processing system                                                         can precisely and automatically                                                         provide samples and                                                         reagents, and can promptly                                                         remove waste. This ensures                                                         accurate analysis results.   |  | The Customer Requirements: 1. To ensure the                                                         accuracy of the spectrum                                                         analysis, the spectrometer                                                         always needs automatic                                                         sampling system to provide                                                         accurate samples and                                                         reagents with a stable                                                         flow rate. The sample                                                         and reagent flow rate                                                         can be changed according                                                         to the substance which                                                         needs to be detected,                                                         to eliminate disturbance                                                         during transfer. The                                                         sampling system should                                                         have good chemical and                                                         abrasion resistance.                                                           2. To ensure the                                                         high efficiency of the                                                         analysis, waste needs                                                         to be promptly removed. 3. For the shear-sensitive                                                         samples, the sampling                                                         system needs to protect                                                         the integrity of the                                                         sample and reduce damaging.                                                             |  | Longer Pump Solution: 1. Longer's Peristaltic                                                         Pumps can effectively                                                         seal tubing without                                                         the need for any valves.                                                         And the pumps have wide                                                         range of flow rate which                                                         can be precisely managed                                                         through the speed control.                                                         The increasing pump                                                         rotor quantity reduces                                                         the pulse and maintains                                                         the stability of the                                                         sample flow. When transferring                                                         the samples and reagents,                                                         the fluid only comes                                                         into contact with the                                                         bore of the tubing,                                                         this eliminates the                                                         contamination between                                                         the pump and fluids.                                                         By changing the tubing,                                                         pumps can transfer different                                                         corrosive and abrasive                                                         fluids without cross-contamination.                                                         Longer’s peristaltic                                                         pump has a variety of                                                         control methods, and                                                         can be integrated into                                                         the control system to                                                         complete the sampling                                                         and waste discharging                                                         function automatically.                                                         Because of the low shear                                                         and gentle pumping action,                                                         Longer’s peristaltic                                                         pump is ideal for the                                                         shear-sensitive substance                                                         transfer.  2. Longer's Industrial                                                         Syringe Pump is extremely                                                         precise for small volume                                                         transfers. The fluid                                                         only comes into contact                                                         with the bore of the                                                         syringe and the tubing                                                         system to eliminate                                                         the contamination between                                                         the pump and fluids.                                                           3. Longer's micro                                                         piston pump is extremely                                                         precise and has an extended                                                         life (10 million cycles),                                                         making it ideal for                                                         the transfer of small                                                         volume samples/reagents,                                                         ensuring the sampling                                                         is accurate and reliable.   |  | Customer Value: 1.High precision                                                         ensures the accurate                                                         sampling and the analysis                                                         result, and could help                                                         achieve automatic function                                                         of the diluting and                                                         preparation of the standard                                                         solution. Longer                                                         high precision micro                                                         piston pump has excellent                                                         dispensing precision:                                                         CV of 100% dispensing                                                         volume<0.1%.
 Dispensing                                                         precision of Longer                                                         industrial syringe pump                                                         CV<0.5%
 Dispensing                                                         precision of Longer                                                         peristaltic pump CV<2%
 2.Remove the waste                                                         in a timely fashionLonger                                                         peristaltic pump has                                                         good self-priming capability                                                         and could develop a                                                         vacuum of -0.95Bar(g)
 Longer                                                         peristaltic pump could                                                         run dry without any                                                         damage.
 With the                                                         fixed speed peristaltic                                                         pump, the waste could                                                         be removed under a stable                                                         flow rate. With the                                                         variable speed peristaltic                                                         pump, the waste could                                                         be removed under variable                                                         flow rate based on the                                                         actual requirement.
 Longer                                                         peristaltic pump could                                                         be remote controlled                                                         through RS485 interface                                                         or analog signal interface.                                                         So the pump can be integrated                                                         into the control system                                                         of the spectrometer                                                         to remove the waste                                                         in a timely fashion.
 3.Suitable for abrasive                                                         liquid with particles                                                         or corrosive liquid                                                         transferring. Gentle                                                         pumping action of Longer                                                         peristaltic pump is                                                         ideal for the semisolids,                                                         heterogeneous mixtures                                                         and liquid with particles.                                                         When transferring the                                                         fluid, the fluid only                                                         contacts the bore of                                                         the tubing. By using                                                         the tubing with good                                                         abrasive resistance,                                                         the pump can be used                                                         to transfer the abrasive                                                         liquid. By using the                                                         tubing with good chemical                                                         resistance, the pump                                                         can be used to transfer                                                         the corrosive liquid.
 Soft                                                         particle size<25%*ID                                                         (tubing inside diameter)
 Hard                                                         particle size<5%*ID                                                         (tubing inside diameter)
 4.Reduce the damaging                                                         and protect the integrity                                                         for the shear-sensitive                                                         samples.The                                                         low shear, gentle pumping                                                         action of peristaltic                                                         pump ensures the substance                                                         will not be damaged.
 5.High reliability                                                         and easy maintenance                                                         of the pump help reduce                                                         the costLonger                                                         peristaltic pump does                                                         not need the valves                                                         and seals when transferring                                                         the fluid, and can run                                                         dry without damage.
 Longer                                                         high precision micro                                                         piston pump has no consumable                                                         parts during the millions                                                         of life time.
 The                                                         only consumable material                                                         of peristaltic pump                                                         is tubing, and the only                                                         consumable material                                                         of industrial syringe                                                         pump is syringe. The                                                         tubing and syringe can                                                         be changed easily, which                                                         reduces the maintenance                                                         cost.
 | 
 | 
 |