    제품명 봄베칼로리미터
    모델명 SDC Series Calorimeter
    제품분류 측정/계측/검사/시험기검사시험기
    사양 하단표기
    가격 가격협의
    세금계산서 가능
    거래방식
    상태
    판매지역 전국
    A/S 여부 가능
    설치 및 시운전 불가능
    상세정보

    Isopheribol Oxygen Bomb Calorimeter 봄베칼로리미터

     

    봄베칼로리미터는 코우크스 및 석탄, 석유 화합물, 시멘트, black meal, 바이오매스, 폐기물, 목재 등의 연소성 물질의 총발열량(gross calorific value)를 빠른 시간 내 측정하는 isopheribol 열량계로서, GB/T213-2008 Calorific Value of Coal, ASTM D5865-2010 Gross Calorific Value, ISO1928 Solid Mineral Fuels 등의 규격 시험을 제공합니다.


    SDC Series Calorimeter
    Calorimeter


    Internal stability

     

    Internal stability is secured with the aid of temperature control device and

    a helix tube within both the lid and the bucket wall. These enable the system

    with constant water temperature even if the ambient temperature fluctuates

    by 10℃ in the single period of testing.


    Power supply stability

     

    Unique design of inverter which can purify and stabilize the power supply, ensures the calorimeter will not be affected by the fluctuation of power voltage (from 160V to 240V) and frequency.

     

    Independent bucket and jacket water system

    Bucket water will be drained to water tank directly after finishing the test, so the inlet and outlet of bucket water will not affect the jacket water.

     

    Constant bucket water volume and temperature

    Constant volumetric tank with temperature controlling device enables a high level of uniformity on both water volume and temperature for each test.

     

    High temperature resolution

    Temperature control utilizes a PT1000 Platinum resistance probe for temperature resolution to the nearest 0.0001k.

     

    Stable and reliable water quality

    Equipped with high quality water purification device, the water quality of each test is guaranteed.

     

    Test Turn Over

    Due to the nature of this water calorimeter, there is no cool down or prepping time in between tests. And with bomb identifier, up to four bombs can be recognized. So, as soon as one test is completed the bomb can be replaced immediately with another to recommence testing.  

     

    High automation

    Automatic oxygen filler equipped, oxygen filling by one press;

    Automatic controlling of water volume, filling, heating, empting and jacket water circulation;

    Automatic sample ignition;

    Automatic temperature rise measurement and result calculation.

     

    Models


    Method

    Isoperibol

    Analysis Time

    SDC311< 11min, SDC313<13min, SDC5015 < 15 min

    Precision

    RSD<0.1%

    Heat capacity stability

     ≤0.20% within three months

    Heat capacity precision

    ≤0.1%

    Temperature resolution

    0.0001K

    Power Requirements

    220 V±10%, 50Hz

    Max Power

    1.5kw

    Gas Requirements

    Oxygen (99.5% purity)

    Water Requirements

    Distilled water

    Standard Layout

    SDC311 Calorimeter

    SDC311 Calorimeter/ Water Tank/Lenovo PC (Desktop)/Printer

    Size

    432*560*393mm

    N.W.

    60kg